| Thread type | 1-inch nominal diameter, 32 threads per inch, Unified 60° thread | The lens thread must match the camera’s C mount thread to prevent cross-threading or insecure mounting. |
| Flange focal distance | 17.526 mm from the mounting shoulder to the image plane | Incorrect spacing can prevent focus or alter the calibrated object-to-image geometry. |
| Mounting interface | Threaded mount; some systems use a locking ring or adapter | A secure, low-play connection is important for repeatable measurement and stable optical alignment. |
| Telecentricity | Object-space, image-space, or bilateral; commonly specified in degrees | Lower angular deviation reduces apparent size changes caused by object position variation. |
| Magnification | Fixed values such as 0.1×, 0.2×, 0.5×, or 1.0× | Magnification determines the field of view and must match the sensor size and inspection area. |
| Working distance | Specified in millimeters; commonly fixed for measurement lenses | The lens must provide enough clearance for the part, lighting, fixtures, and protective windows. |
| Image circle | Must be larger than the sensor diagonal; a practical margin is recommended | Insufficient coverage causes dark corners, vignetting, reduced illumination, or unusable pixels. |
| F-number and numerical aperture | Select according to resolution, depth of field, and available illumination | Stopping down can increase depth of field, while diffraction and light loss may reduce fine-detail performance. |
| Sensor pixel size | Compare the lens resolution with the camera pixel pitch | A lens with insufficient resolution can limit measurement accuracy even when the sensor is fully covered. |
| Back focal clearance | Confirm the rear optical assembly does not contact the camera filter or protective glass | Large sensors and specialized cameras may require additional mechanical clearance behind the C mount. |