| Manufacturer 01 | General low-voltage distribution ACBs | 630–6,300 A | Up to 1,000 V AC | 50–100 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; GB/T 14048.2 | Electronic LSI / LSIG | Modbus-RTU available on selected models | High potential |
| Manufacturer 02 | Fixed and draw-out ACBs for main switchboards | 400–6,300 A | Up to 1,000 V AC | 50–85 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; CCC where applicable | Electronic LI / LSI | RS-485 communication on selected trip units | High potential |
| Manufacturer 03 | Industrial and commercial power distribution | 630–4,000 A | Up to 1,000 V AC | 42–80 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; GB/T 14048.2 | Electronic LSI / LSIG | Modbus-RTU or dry-contact indication | High potential |
| Manufacturer 04 | High-current incomer and bus-coupler applications | 1,000–6,300 A | Up to 1,000 V AC | 65–100 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; type-test documentation required | Electronic LSI / LSIG with zone selectivity | Modbus-RTU; gateway options may be available | Verify test reports |
| Manufacturer 05 | Compact draw-out ACB solutions | 630–3,200 A | Up to 1,000 V AC | 42–65 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; GB/T 14048.2 | Electronic LI / LSI | Auxiliary contacts; communication subject to model | Good potential |
| Manufacturer 06 | Generator, ATS and emergency-power applications | 630–4,000 A | Up to 1,000 V AC | 50–85 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; generator coordination data required | Electronic LSIG; adjustable short-time protection | Modbus-RTU available on selected models | Verify coordination |
| Manufacturer 07 | Data-center and critical-load distribution | 800–6,300 A | Up to 1,000 V AC | 65–100 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; IEC 61439 system coordination | Electronic LSIG with metering functions | Modbus-RTU; Ethernet gateway may be required | Verify selectivity |
| Manufacturer 08 | Export-oriented low-voltage switchgear projects | 630–6,300 A | Up to 1,000 V AC | 50–100 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; destination-market certification | Electronic LSI / LSIG | Modbus-RTU and auxiliary signaling options | Check target-market approval |
| Manufacturer 09 | OEM and customized switchboard packages | 400–4,000 A | Up to 1,000 V AC | 42–80 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; routine-test records required | Electronic LI / LSI / LSIG | Communication depends on control-unit configuration | Assess customization |
| Manufacturer 10 | Cost-sensitive commercial and industrial projects | 630–3,200 A | Up to 1,000 V AC | 42–65 kA at 400/415 V AC | 3P / 4P | IEC 60947-2; GB/T 14048.2 | Electronic LI / LSI | Basic auxiliary contacts; communication optional | Good potential |